Experimental study on the effect of different fatigue loading method on the property of metal cantilever beamPaper: icaf2023 Tracking Number 26 PPT: not available Session: Poster pitches day 2 Room: Theatre room: plenary Session start: 10:00 Tue 27 Jun 2023 Wei Cui cuiwei_buaa@163.com Affifliation: Dingni He shine.1990.hi@163.com Affifliation: Jianjian Yu yujianjian000@sohu.com Affifliation: Yunfei Liao liaoyunfei@samst.net Affifliation: Topics: - Full-scale fatigue testing of aircraft and aircraft structural components (Genral Topics) Abstract: In order to investigate the influence of different fatigue loading methods on the property of metal cantilever, the resonant fatigue testing system and the corresponding conventional fatigue testing system were designed respectively based on the electromagnetic vibration table, and the bending fatigue tests were conducted on LY12CZ aluminum alloy cantilever beam specimens. A special progressive analysis based on damage equivalence was used to obtain S-N curves under resonance environment in the range of 1×105-1×107 cycles. The results show that the fatigue limit of LY12CZ aluminum alloy under bending resonance environment is 74.6MPa and the fatigue limit under conventional condition is 76.2MPa at 1×107cycles. When the number of cycles is less than 5×106, the bending resonant fatigue property of LY12CZ aluminum alloy is significantly different from the conventional fatigue property, while in the range of 5×106-1×107cycles, there is little difference between the two properties. |